Design of Data-Acquisition Hardware Circuitry for a Legacy Obara STN21 Resistance Spot-Weld Controller

A. R. Arvind *

Ashok Leyland, Chennai, India.

S. Swetha Sri

Easwari Engineering College, Chennai, India.

D. L. Tharanya

Easwari Engineering College, Chennai, India.

S. Uma Maheswari

Department of ECE, Easwari Engineering College, Chennai, India.

S. Suresh

Project Planning Department, Ashok Leyland, Chennai, Tamil Nadu, India.

Ravi Teja Eegalapati

Project Planning Department, Ashok Leyland, Chennai, Tamil Nadu, India.

*Author to whom correspondence should be addressed.


Abstract

Legacy resistance spot welding (RSW) timers on many automotive body-in-white lines expose weld parameters only through a handheld teaching pendant, which blocks automated quality logging. This paper presents the design of a non-intrusive, read-only data-acquisition (DAQ) node for the Obara STN21 single-phase AC weld timer, developed for a digitalisation project at a commercial vehicle OEM in South India. Analysis of the controller manual shows that its only documented machine-readable fieldbus is an optional DeviceNet slave interface with a 5-byte input image, not the RS-485 link assumed in the project brief, so the node measures the process externally. Two circuits are compared in a ten-criterion matrix: Option A, with per-channel AMC1200 isolation amplifiers, a 6N137 status optocoupler, and an RS-485/Modbus link, and Option B, with whole-node isolation, PC817 status inputs and isolated Ethernet. Option A was selected for the first build. Design calculations expose integrator-range, ADC-throughput, and component-rating issues in both drafts, including load-cell grounding, and propose corrections; the integrator and load-cell corrections are built into the selected Option A design, while the ADC-simultaneity limitation remains open. A low-voltage prototype (ESP32 with ADS1115, potentiometer-simulated sensors) verified I²C communication, full-scale scaling within the reading precision, weld start/stop detection at a 1 kA threshold, per-weld summaries, and channel independence. Validation under live welding conditions remains future work.

Keywords: Data acquisition, dynamic resistance, ESP32, galvanic isolation, industry 4.0 retrofit, resistance spot welding, Rogowski coil


How to Cite

Arvind, A. R., S. Swetha Sri, D. L. Tharanya, S. Uma Maheswari, S. Suresh, and Ravi Teja Eegalapati. 2026. “Design of Data-Acquisition Hardware Circuitry for a Legacy Obara STN21 Resistance Spot-Weld Controller”. Asian Journal of Advanced Research and Reports 20 (12):97-113. https://doi.org/10.9734/ajarr/2026/v20i121519.

Downloads

Download data is not yet available.